Predictor | Mitochondrial | Other | Weight | |
---|---|---|---|---|
Mitoprot
(?)
Score represents the predicted probability that the protein is targeted to mitochondria (mitochondrial score) or not (other score) according to Mitoprot (click to reach). If multiple isofoms of the same protein are available the highest scores are shown for each compartment. Probability values >0.95 are multiplied by 2 as a bonus for the score. If multiple proteins are associated with the reaction, the maximum score for each compartment is presented. See corresponding gene pages (see table below) for the scores of individual proteins. |
0.07 | 1.99 | 2.0 | |
MitoMiner
(?)
Score evaluates the evidence for mitochondrial targeting based on the orthologs in 12 eukaryotic model organisms that are in the MitoMiner database (click to reach). Takes a value between 0 and 1 as a function of the ratio of orthologs that have hits (contributes to the mitochondrial score) or no hits (determines the other score) in the database. Mitochondrial score is also a function of the strength of the evidence for the orthologs found in the database (experimental evidence is given a higher weight than theoretical evidence during scoring). If multiple proteins are associated with the reaction, the maximum score for each compartment is presented. See corresponding gene pages (see table below) for the scores of individual proteins. |
0.00 | 1.00 | 1.5 |
Specific protein |
UniProt
(?)
Score shows the subcellular localization of proteins encoded by this gene as reported in UniProt (click to reach) in October 2014. Takes a value of either 0 (not reported to be localized to the pertaining compartment) or 1 (reported to be localized to the pertaining compartment). If multiple proteins are associated with the reaction, the maximum score for each compartment is presented. See corresponding gene pages (see table below) for the scores of individual proteins. |
Not available | Not available | 1.0 | |
Org. DB
(?)
Score shows the subcellular localization of proteins encoded by this gene as reported in Organelle Database (click to reach). Takes a value of either 0 (not reported to be localized to the pertaining compartment) or 1 (reported to be localized to the pertaining compartment). If multiple proteins are associated with the reaction, the maximum score for each compartment is presented. See corresponding gene pages (see table below) for the scores of individual proteins. |
Not available | Not available | 1.0 | |
BRENDA
(?)
Score represents the proportion of proteins experimentally localized to the indicated compartment as reported in the BRENDA database (click to reach) for the generic enzyme associated with this reaction. If one of the reported localization experiments for a compartment is carried out in C. elegans, a score of 1.0 is granted regardless of reports from other organisms. If multiple enzymes are associated with the reaction, the maximum score for each compartment is presented. |
0.00 | 1.00 | 1.0 | Generic enzyme |
BiGG (?) Score represents 0.5 times the number of eukaryotic models with the indicated compartment for this reaction in the BiGG database. Since there are two eukaryotic models, the maximum score is 1.0. | Not available | Not available | 1.5 | Reaction |
FBA
(?)
Score shows whether the reaction is useful when it is placed in the indicated compartment based on flux balance analysis. A score of 0 generally indicates no flux carrying capacity, while 1 indicates that the reaction can carry flux. In some cases, a score of 0 also indicates flux carrying as part of a looping pathway, as a looping flux flow does not warrant the contribution of the reaction to metabolic processes in a comparment. If the flux also contributes to biomass or energy generation when placed in the pertaining compartment, a bonus score of 1 is added to reach a maximum score of 2. This score is valid only for PRIME model reactions, and therefore, is "not applicable" to others. |
0 | 1 | 2.0 | |
Overall (?) Obtained by multiplying each score by the corresponding weight and summing the products. A value >6.2 is considered as sufficient evidence for localization to the pertaining compartment. If neither compartment reaches this threshold, the greater score decides. However, if two scores are within 1.2 of each other, reaction is considered to be localized to both compartments. If FBA score is not available, the first threshold is reduced to 4.2. Exceptions (i.e., cases when these rules are overridden by other criteria) are idicated in general comments to the reaction. | 0.1 | 8.5 |